Polarization Calibration: Difference between revisions

From EOVSA Wiki
Jump to navigation Jump to search
Line 4: Line 4:
:<math> L = X - iY </math>
:<math> L = X - iY </math>
In terms of autocorrelation powers, we have the 4 polarization products XX*, YY*, XY* and YX*, where the * denotes complex conjugation.  The quantities RR* and LL* are then
In terms of autocorrelation powers, we have the 4 polarization products XX*, YY*, XY* and YX*, where the * denotes complex conjugation.  The quantities RR* and LL* are then
:<math> RR* = (X + iY)(X + iY)* = XX* - iXY* + iYX* +YY* </math>
:<math> RR^* = (X + iY)(X + iY)^* = XX^* - iXY^* + iYX^* +YY^* </math>


== Polarization Mixing Correction ==
== Polarization Mixing Correction ==
Due to relative feed rotation between az-al mounted antennas and equatorial mounted antennas
Due to relative feed rotation between az-al mounted antennas and equatorial mounted antennas

Revision as of 19:52, 24 September 2016

Linear to Circular Conversion

At EOVSA’s linear feeds, in the electric field the linear polarization, X and Y, relates to RCP and LCP (R and L) as:

In terms of autocorrelation powers, we have the 4 polarization products XX*, YY*, XY* and YX*, where the * denotes complex conjugation. The quantities RR* and LL* are then

Polarization Mixing Correction

Due to relative feed rotation between az-al mounted antennas and equatorial mounted antennas